To sense the non-electric active of urea, the present method uses an enzyme in electrochemical sensors. The enzyme-based sensor consists of an enzyme (urease) and a mediator, which distinguishes the urease-catalyzed hydrolysis products [8]. However, the enzymatic sensor is complex, unstable, and costly, so non-enzyme sensors are better suited for wearable sensor devices. Nickel-based catalysts with nanostructures, large surface area, good electrical conductivity, and low cost are the best nominees for urea detection as they oxidize urea without enzymes [9]. Recently, a polymer-type substrate has been utilized for the flexible and wearable sensor device which requires porous and conductive polymers.
Herein, we investigated a facile approach to form nickel oxyhydroxide with metal (metal-NiOOH) based flexible electrochemical sensor by electrospinning method. The morphology and the structure of the metal-NiOOH catalysts were observed using transmission electron microscopy, scanning electron microscopy, and X-ray diffraction. The metal-NiOOH catalysts with polymer showed excellent flexibility and competent linear sensitivity to urea electrooxidation in the physiological concentration area. A comprehensive investigation of the performances regarding metal-NiOOH as a catalyst in a sweat-based sensor will be presented.
References
- Feiner, Ron, et al. "Engineered hybrid cardiac patches with multifunctional electronics for online monitoring and regulation of tissue function." Nature materials 15.6 (2016): 679.
- Liu, Yuhao, Matt Pharr, and Giovanni Antonio Salvatore. "Lab-on-skin: a review of flexible and stretchable electronics for wearable health monitoring." ACS nano 11.10 (2017): 9614-9635.
- Pickup, John C., et al. "In vivo glucose monitoring: the clinical reality and the promise." Biosensors and Bioelectronics 20.10 (2005): 1897-1902.
- D'Apolito, Maria, et al. "Urea-induced ROS cause endothelial dysfunction in chronic renal failure." Atherosclerosis 239.2 (2015): 393-400.
- Thudichum, J. L. W. "On the analysis of urea in urine for clinical purposes." British medical journal 1.38 (1857): 788
- Stefaniak, Aleksandr B., and Christopher J. Harvey. "Dissolution of materials in artificial skin surface film liquids." Toxicology in Vitro 20.8 (2006): 1265-1283.
- Kazory, Amir. "Emergence of blood urea nitrogen as a biomarker of neurohormonal activation in heart failure." The American journal of cardiology 106.5 (2010): 694-700.
- Liu, Yan-Ling, et al. "Flexible electrochemical urea sensor based on surface molecularly imprinted nanotubes for detection of human sweat." Analytical chemistry 90.21 (2018): 13081-13087.
- Mahshid, Sahar Sadat, et al. "Template-based electrodeposition of Pt/Ni nanowires and its catalytic activity towards glucose oxidation." Electrochimica Acta 58 (2011): 551-555.
Acknowledgement
This work was supported by Agency for Defense Development (ADD) as global cooperative research for high performance and light weight bio-urine based fuel cell (UD160050BD) and the Ocean University of China-Auburn University (OUC-AU) Grants program.