This work presents a systematic study to elucidate the effect of PTL properties (morphology, thickness, and porosity) and their impact on PEMWE performance under different operating conditions. Polarization curves with different anode PTL (felt, sinter and pore graded hierarchical PTL) are presented in Figure 1a. The separation of mass transport resistance and the contract resistance for the different PTLs will be elucidated to show the impact of water management and interfacial contact. Mass transport in an operating electrolyzer is also studied by estimating the water content using neutron imaging. Figure 1b shows water thickness across a membrane electrode assembly (MEA) with a pore graded hierarchical PTL in anode at different current densities. Water content across the MEA with different PTL is also studied. The cells with these PTLs were evaluated in operando using micro x-ray computed tomography (CT) and x-ray radiography. The x-ray techniques revealed oxygen distribution within the PTLs on the pore-scale at varied current densities, complementing neutron imaging water thickness studies and providing micro-scale insight into transport.
Acknowledgment
This research is supported by the U.S. Department of Energy (DOE) Hydrogen and Fuel Cell Technologies Office, through the H2NEW consortium.
References
- J. K. Lee, C. Lee, K. F. Fahy, B. Zhao, J. M. LaManna, E. Baltic, D. L. Jacobson, D. S. Hussey and A. Bazylak, Cell Reports Physical Science, 1, 100147 (2020).
- T. Schuler, J. M. Ciccone, B. Krentscher, F. Marone, C. Peter, T. J. Schmidt and F. N. Büchi, Advanced Energy Materials, 10, 1903216 (2020).
- P. Lettenmeier, S. Kolb, F. Burggraf, A. S. Gago and K. A. Friedrich, Journal of Power Sources, 311, 153 (2016).