The first approach is based on polarizing the complete electroless system, allowing external current to flow simultaneously with the electroless process. From the difference between the measured amount of deposited copper and the total external current, the glyoxylic acid reaction rate can be determined. Translating the copper and glyoxylic acid reaction rates to currents, polarization curves can be generated for the two reactions (copper deposition and glyoxylic acid oxidation) as they occur in the full electroless system. As shown in Fig. 1, these rates are significantly different in the combined system as compared to the separately measured polarization curves. In particular, the copper deposition rate is significantly enhanced in the full electroless system as indicated in Fig. 1.
A second approach taken to analyze and model the electroless system is based on formulating rate expressions, in terms of reaction rate power law, for each of the two redox reactions taking place simultaneously in the electroless process. The rate expressions incorporate the reactants and products concentrations raised to arbitrary powers, and potential-dependent Arrhenius type rate constants. As both reactions occur in electroless plating on the same surface in the absence of external current, their rates must be equal. From this equality, separate expressions for current density and mixed potential are developed. The rate constants and powers are determined experimentally by seeking best-fit between the rate expression and measured electroless deposition rates across wide concentration ranges, resulting in equations 1 and 2.
The effect of transport was also incorporated in the model, as depletion near the surface changes the reactants concentration at the reaction site. To account for the transport dependence, electroless deposition experiments were performed on a rotating disk electrode (RDE). The model predicts that at lower rotation speed, both the surface concentrations of the reactants and the ensuing reaction rate will be lower. However, initially measured plating rates were significantly lower than predicted at the lower rotation rates. This was identified as being the consequence of partial surface blockage of the downward facing RDE by bubbles of hydrogen evolved in the reaction. Once the surface bubbles were eliminated, good agreement between the model predictions and actual measurements was noted, as shown in Fig. 2.
The final result is a predictive, semi-empirical model for both deposition rate and the mixed potential for electroless plating which accounts for reactant concentrations and transport effects. More generally, this study presents a framework for characterizing other electroless systems for better understanding, scaling, and control of the process.
Acknowledgements
Atotech GMBH is acknowledged for funding this study and for providing helpful input.
References
- Wagner, C., & Traud, W. (1938). On the Interpretation of Corrosion Processes through the Superposition of Electrochemical Partial Processes and on the Potential of Mixed Electrodes. Zeitschriff fur Elektrochemie.
- Yu, Lu, et al. "Autocatalysis during Electroless Copper Deposition using Glyoxylic Acid as Reducing Agent." Journal of the Electrochemmical Society (2013): D3004-D3008.